<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Spectrophotometers Archive - Abacus Analytical Systems</title>
	<atom:link href="https://abacus-lab.de/en/portfolio_category/spectrophotometers/feed/" rel="self" type="application/rss+xml" />
	<link>https://abacus-lab.de/en/portfolio_category/spectrophotometers/</link>
	<description>Analytical Chemistry &#124; Biotechnology &#124; Bioscience</description>
	<lastBuildDate>Mon, 07 Dec 2020 15:54:29 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.1.7</generator>

<image>
	<url>https://abacus-lab.de/wp-content/uploads/2020/07/cropped-AbacusThumbnail-1-32x32.png</url>
	<title>Spectrophotometers Archive - Abacus Analytical Systems</title>
	<link>https://abacus-lab.de/en/portfolio_category/spectrophotometers/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>M550 Spektrophotometer  Copy</title>
		<link>https://abacus-lab.de/en/portfolio-items/m550-copy/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=m550-copy</link>
					<comments>https://abacus-lab.de/en/portfolio-items/m550-copy/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 07 Dec 2020 09:59:37 +0000</pubDate>
				<guid isPermaLink="false">https://abacus-lab.com/portfolio-items/m550-copy/</guid>

					<description><![CDATA[<p>Das Spektrometer für die High-End-Analyse in Industrie und an Universitäten</p>
<p>paralleler Proben- &amp; Referenzstrahlengang<br />
	Wellenlängenbereich 190 - 1100 nm<br />
 	variabler Bandpass &amp; feste Optionen<br />
 	geringes Streulicht (&lt; 0,05%T)<br />
 	GLP-Konformität möglich<br />
 	Chroma-Software verfügbar (optional)</p>
<p>Der Beitrag <a rel="nofollow" href="https://abacus-lab.de/en/portfolio-items/m550-copy/">M550 Spektrophotometer  Copy</a> erschien zuerst auf <a rel="nofollow" href="https://abacus-lab.de/en/">Abacus Analytical Systems</a>.</p>
]]></description>
		
					<wfw:commentRss>https://abacus-lab.de/en/portfolio-items/m550-copy/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>M550 Spectrophotometer</title>
		<link>https://abacus-lab.de/en/portfolio-items/m550/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=m550</link>
					<comments>https://abacus-lab.de/en/portfolio-items/m550/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 14:15:59 +0000</pubDate>
				<guid isPermaLink="false">https://abacus-lab.com/portfolio-items/m501-copy/</guid>

					<description><![CDATA[<p>The spectrometer for high-end analysis in industry and universities</p>
<p>parallel sample &amp; reference beam<br />
	Wavelength range 190 - 1100nm<br />
 	variable Bandpass &amp; fixed options<br />
 	Low stray light (&lt; 0.05%T)<br />
 	GLP compliance possible<br />
 	Chroma Software availiable (optional)</p>
<p>Der Beitrag <a rel="nofollow" href="https://abacus-lab.de/en/portfolio-items/m550/">M550 Spectrophotometer</a> erschien zuerst auf <a rel="nofollow" href="https://abacus-lab.de/en/">Abacus Analytical Systems</a>.</p>
]]></description>
		
					<wfw:commentRss>https://abacus-lab.de/en/portfolio-items/m550/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>M501 Spectrophotometer</title>
		<link>https://abacus-lab.de/en/portfolio-items/m501/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=m501</link>
					<comments>https://abacus-lab.de/en/portfolio-items/m501/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 13:52:32 +0000</pubDate>
				<guid isPermaLink="false">https://abacus-lab.com/portfolio-items/m509t-copy/</guid>

					<description><![CDATA[<p>The spectrometer for advanced analysis in industry and academia</p>
<p>single Beam UV/VIS spectrometer<br />
	Wavelength range 190 - 1100nm<br />
 	Bandwidth 4 nm (optional 2 nm)<br />
 	Low stray light (&lt; 0.05%T)<br />
 	GLP compliance possible</p>
<p>Der Beitrag <a rel="nofollow" href="https://abacus-lab.de/en/portfolio-items/m501/">M501 Spectrophotometer</a> erschien zuerst auf <a rel="nofollow" href="https://abacus-lab.de/en/">Abacus Analytical Systems</a>.</p>
]]></description>
		
					<wfw:commentRss>https://abacus-lab.de/en/portfolio-items/m501/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>M509T Spectrophotometer</title>
		<link>https://abacus-lab.de/en/portfolio-items/m509t/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=m509t</link>
					<comments>https://abacus-lab.de/en/portfolio-items/m509t/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 13:27:47 +0000</pubDate>
				<guid isPermaLink="false">https://abacus-lab.com/portfolio-items/m209t-copy/</guid>

					<description><![CDATA[<p>The spectrometer for reliable analysis in industry and at universities</p>
<p>Big touch screen for local control without PC<br />
	Onboard control software<br />
	Wavelength range 190 - 1000nm<br />
 	Bandwidth 2 nm</p>
<p>Der Beitrag <a rel="nofollow" href="https://abacus-lab.de/en/portfolio-items/m509t/">M509T Spectrophotometer</a> erschien zuerst auf <a rel="nofollow" href="https://abacus-lab.de/en/">Abacus Analytical Systems</a>.</p>
]]></description>
		
					<wfw:commentRss>https://abacus-lab.de/en/portfolio-items/m509t/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>M209T Spectrophotometer</title>
		<link>https://abacus-lab.de/en/portfolio-items/m209t/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=m209t</link>
					<comments>https://abacus-lab.de/en/portfolio-items/m209t/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 12:38:03 +0000</pubDate>
				<guid isPermaLink="false">https://abacus-lab.com/portfolio-items/m508-copy/</guid>

					<description><![CDATA[<p>The new Camspec M209T:designed for easy routine operation with local control and focus on high durability.</p>
<p>Big touch screen for local control without PC<br />
 	Onboard control software<br />
 	Stores up to hundred methods/results<br />
 	Wavelength range 325 - 1000nm<br />
 	Bandwidth 2nm<br />
 	Large sample compartment</p>
<p>Der Beitrag <a rel="nofollow" href="https://abacus-lab.de/en/portfolio-items/m209t/">M209T Spectrophotometer</a> erschien zuerst auf <a rel="nofollow" href="https://abacus-lab.de/en/">Abacus Analytical Systems</a>.</p>
]]></description>
		
					<wfw:commentRss>https://abacus-lab.de/en/portfolio-items/m209t/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>M508 Spectrophotometer</title>
		<link>https://abacus-lab.de/en/portfolio-items/m508/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=m508</link>
					<comments>https://abacus-lab.de/en/portfolio-items/m508/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 11:32:44 +0000</pubDate>
				<guid isPermaLink="false">https://abacus-lab.com/portfolio-items/m108-copy/</guid>

					<description><![CDATA[<p>The basic programmable UV-VIS spectrometer for routine operation</p>
<p>Stores up to two hundred methods/results<br />
 	Selectable wavelength calibration and dark current measurement<br />
 	Wavelength range 200 - 1000nm<br />
 	Bandwidth 4nm<br />
 	Large sample compartment<br />
 	Manual 4-cell changer<br />
 	Wide range of accessories</p>
<p>Der Beitrag <a rel="nofollow" href="https://abacus-lab.de/en/portfolio-items/m508/">M508 Spectrophotometer</a> erschien zuerst auf <a rel="nofollow" href="https://abacus-lab.de/en/">Abacus Analytical Systems</a>.</p>
]]></description>
		
					<wfw:commentRss>https://abacus-lab.de/en/portfolio-items/m508/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>M108 Spectrophotometer</title>
		<link>https://abacus-lab.de/en/portfolio-items/m108/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=m108</link>
					<comments>https://abacus-lab.de/en/portfolio-items/m108/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Fri, 17 Jul 2020 12:13:33 +0000</pubDate>
				<guid isPermaLink="false">https://abacus-lab.com/portfolio-items/tea4000-copy/</guid>

					<description><![CDATA[<p>The basic programmable VIS spectrometer for routine operation</p>
<p>Stores up to two hundred methods/results<br />
 	Selectable wavelength calibration and dark current measurement<br />
 	Wavelength range 325 - 1000nm<br />
 	Bandwidth 4nm<br />
 	Large sample compartment<br />
 	Manual 4-cell changer<br />
 	Wide range of accessories</p>
<p>Der Beitrag <a rel="nofollow" href="https://abacus-lab.de/en/portfolio-items/m108/">M108 Spectrophotometer</a> erschien zuerst auf <a rel="nofollow" href="https://abacus-lab.de/en/">Abacus Analytical Systems</a>.</p>
]]></description>
		
					<wfw:commentRss>https://abacus-lab.de/en/portfolio-items/m108/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
