{"id":34729,"date":"2020-10-05T16:15:59","date_gmt":"2020-10-05T14:15:59","guid":{"rendered":"https:\/\/abacus-lab.com\/portfolio-items\/m501-copy\/"},"modified":"2020-12-07T10:08:22","modified_gmt":"2020-12-07T09:08:22","slug":"m550","status":"publish","type":"avada_portfolio","link":"https:\/\/abacus-lab.de\/en\/portfolio-items\/m550\/","title":{"rendered":"M550 Spectrophotometer"},"content":{"rendered":"<div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-1 bilder nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;\" id=\"bilder\" ><div class=\"fusion-builder-row fusion-row\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-0 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last\" style=\"--awb-bg-size:cover;\"><div class=\"fusion-column-wrapper fusion-flex-column-wrapper-legacy\"><div class=\"fusion-image-element in-legacy-container\" style=\"--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-1 hover-type-none\"><img decoding=\"async\" width=\"1601\" height=\"387\" title=\"Banner Camspec M550 1600&#215;390\" src=\"https:\/\/abacus-lab.com\/wp-content\/uploads\/2020\/10\/Banner-Camspec-M550-1600x390-1.png\" alt class=\"img-responsive wp-image-34730\" srcset=\"https:\/\/abacus-lab.de\/wp-content\/uploads\/2020\/10\/Banner-Camspec-M550-1600x390-1-200x48.png 200w, https:\/\/abacus-lab.de\/wp-content\/uploads\/2020\/10\/Banner-Camspec-M550-1600x390-1-400x97.png 400w, https:\/\/abacus-lab.de\/wp-content\/uploads\/2020\/10\/Banner-Camspec-M550-1600x390-1-600x145.png 600w, https:\/\/abacus-lab.de\/wp-content\/uploads\/2020\/10\/Banner-Camspec-M550-1600x390-1-800x193.png 800w, https:\/\/abacus-lab.de\/wp-content\/uploads\/2020\/10\/Banner-Camspec-M550-1600x390-1-1200x290.png 1200w, https:\/\/abacus-lab.de\/wp-content\/uploads\/2020\/10\/Banner-Camspec-M550-1600x390-1.png 1601w\" sizes=\"(max-width: 800px) 100vw, 1200px\" \/><\/span><\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><\/div><\/div><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-2 fusion-parallax-none nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-background-image:url(&quot;https:\/\/abacus-lab.com\/wp-content\/uploads\/2018\/07\/BG_15.jpg&quot;);--awb-background-size:cover;\" ><div class=\"fusion-builder-row fusion-row\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-1 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last\" style=\"--awb-bg-size:cover;\"><div class=\"fusion-column-wrapper fusion-flex-column-wrapper-legacy\"><div class=\"fusion-sep-clear\"><\/div><div class=\"fusion-separator fusion-full-width-sep\" style=\"margin-left: auto;margin-right: auto;margin-top:20px;width:100%;\"><div class=\"fusion-separator-border sep-double\" style=\"--awb-height:20px;--awb-amount:20px;--awb-sep-color:rgba(224,222,222,0);border-color:rgba(224,222,222,0);border-top-width:1px;border-bottom-width:1px;\"><\/div><\/div><div class=\"fusion-sep-clear\"><\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-2 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last\" style=\"--awb-padding-top:20px;--awb-padding-right:20px;--awb-padding-bottom:20px;--awb-padding-left:20px;--awb-bg-color:rgba(244,244,244,0.56);--awb-bg-size:cover;--awb-margin-top:20px;\"><div class=\"fusion-column-wrapper fusion-flex-column-wrapper-legacy\"><div class=\"fusion-text fusion-text-1\"><h1><span data-sheets-value=\"{\" data-sheets-userformat=\"{\">M550<\/span><\/h1>\n<p>The double beam scanning UV-VIS spectrometer for high end applications<\/p>\n<\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-3 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last\" style=\"--awb-bg-size:cover;\"><div class=\"fusion-column-wrapper fusion-flex-column-wrapper-legacy\"><div class=\"fusion-tabs fusion-tabs-1 classic nav-is-justified horizontal-tabs icon-position-left mobile-mode-accordion\" style=\"--awb-title-border-radius-top-left:0px;--awb-title-border-radius-top-right:0px;--awb-title-border-radius-bottom-right:0px;--awb-title-border-radius-bottom-left:0px;--awb-inactive-color:#ebeaea;--awb-background-color:#ffffff;--awb-border-color:#ebeaea;--awb-active-border-color:#eba931;\"><div class=\"nav\"><ul class=\"nav-tabs nav-justified\" role=\"tablist\"><li class=\"active\" role=\"presentation\"><a class=\"tab-link\" data-toggle=\"tab\" role=\"tab\" aria-controls=\"tab-08612c51264d88a67e2\" aria-selected=\"true\" id=\"fusion-tab-description\" href=\"#tab-08612c51264d88a67e2\"><h4 class=\"fusion-tab-heading\">Description<\/h4><\/a><\/li><li role=\"presentation\"><a class=\"tab-link\" data-toggle=\"tab\" role=\"tab\" aria-controls=\"tab-d95297fbde1663ef923\" aria-selected=\"false\" tabindex=\"-1\" id=\"fusion-tab-specifications\" href=\"#tab-d95297fbde1663ef923\"><h4 class=\"fusion-tab-heading\">Specifications<\/h4><\/a><\/li><li role=\"presentation\"><a class=\"tab-link\" data-toggle=\"tab\" role=\"tab\" aria-controls=\"tab-ec6298d5e9aa3f32803\" aria-selected=\"false\" tabindex=\"-1\" id=\"fusion-tab-accessories&amp;options\" href=\"#tab-ec6298d5e9aa3f32803\"><h4 class=\"fusion-tab-heading\">Accessories &amp; Options<\/h4><\/a><\/li><li role=\"presentation\"><a class=\"tab-link\" data-toggle=\"tab\" role=\"tab\" aria-controls=\"tab-c458542268928c01019\" aria-selected=\"false\" tabindex=\"-1\" id=\"fusion-tab-literature\" href=\"#tab-c458542268928c01019\"><h4 class=\"fusion-tab-heading\">Literature<\/h4><\/a><\/li><li role=\"presentation\"><a class=\"tab-link\" data-toggle=\"tab\" role=\"tab\" aria-controls=\"tab-56fa9d59519ccb93027\" aria-selected=\"false\" tabindex=\"-1\" id=\"fusion-tab-videos\" href=\"#tab-56fa9d59519ccb93027\"><h4 class=\"fusion-tab-heading\">Videos<\/h4><\/a><\/li><\/ul><\/div><div class=\"tab-content\"><div class=\"nav fusion-mobile-tab-nav\"><ul class=\"nav-tabs nav-justified\" role=\"tablist\"><li class=\"active\" role=\"presentation\"><a class=\"tab-link\" data-toggle=\"tab\" role=\"tab\" aria-controls=\"tab-08612c51264d88a67e2\" aria-selected=\"true\" id=\"mobile-fusion-tab-description\" href=\"#tab-08612c51264d88a67e2\"><h4 class=\"fusion-tab-heading\">Description<\/h4><\/a><\/li><\/ul><\/div><div class=\"tab-pane fade fusion-clearfix in active\" role=\"tabpanel\" tabindex=\"0\" aria-labelledby=\"fusion-tab-description\" id=\"tab-08612c51264d88a67e2\">\n<p><strong>The spectrometer for high-end analysis in industry and universities<\/strong><\/p>\n<p>The Camspec M550 is a true double beam UV-Vis spectrophotometer with parallel sample and reference beam paths. It is available in different options from variable to fixed 1.5 nm bandpass. The specifications meet the expectations of a high-end instrument designed for both research and routine use with high demands.<br \/>\nThe M550 is compliant with all current US and European Pharmacopoeia guidelines. Thanks to its high-end features it is also suitable for the highest demands in the pharmaceutical industry, such as applications requiring FDA (US Food and Drug Administration) approval. Furthermore, it is optionally available as a dedicated system for specific applications such as color measurement with the Chroma software.<br \/>\nThe M550 can be controlled either by the Camspec UV Analyst software or via the LCD display and solvent resistant keypad.<\/p>\n<p><strong>Some of the functions of the M550 at a glance:<\/strong><\/p>\n<ul>\n<li>Local control without PC with all modes<\/li>\n<li>Includes basic mode, wavelength scanning, kinetics mode, multi-wavelength, performance validation, DNA\/Protein and quantitative measurements<\/li>\n<li>Wavelength range 190 &#8211; 1100nm<\/li>\n<li>Bandwidth variable (0.1, 0.5, 1, 2,4 nm) &#8211; (optional fixed 1.0, &lt;1.8 nm)<\/li>\n<li>Low stray light (&lt; 0.05%T)<\/li>\n<li>Optional software for PC control<\/li>\n<li>GLP compliance possible<\/li>\n<li>Chroma Software compatible (optional)<\/li>\n<\/ul>\n<\/div><div class=\"nav fusion-mobile-tab-nav\"><ul class=\"nav-tabs nav-justified\" role=\"tablist\"><li role=\"presentation\"><a class=\"tab-link\" data-toggle=\"tab\" role=\"tab\" aria-controls=\"tab-d95297fbde1663ef923\" aria-selected=\"false\" tabindex=\"-1\" id=\"mobile-fusion-tab-specifications\" href=\"#tab-d95297fbde1663ef923\"><h4 class=\"fusion-tab-heading\">Specifications<\/h4><\/a><\/li><\/ul><\/div><div class=\"tab-pane fade fusion-clearfix\" role=\"tabpanel\" tabindex=\"0\" aria-labelledby=\"fusion-tab-specifications\" id=\"tab-d95297fbde1663ef923\">\n<div class=\"su-row\"><div class=\"su-column su-column-size-1-2\"><div class=\"su-column-inner su-u-clearfix su-u-trim\">\n<p><strong>Type:<\/strong> Spectrophotometer for UV &amp; Visible Light<br \/>\n<strong>Spectral range:<\/strong> 190 &#8211; 1100 nm<br \/>\n<strong>Wavelength Accuracy:<\/strong> \u00b1 0.3 nm<br \/>\n<strong>Wavelength Repeatability:<\/strong> \u00b1 0.05 nm<br \/>\n<strong>Bandpass:<\/strong> variable (0.1, 0.5, 1, 2,4 nm)\/(optional fixed 1.0, &gt;1.8 nm)<br \/>\n<strong>Baseline Flatness:<\/strong> &lt; 0.002 (after 1h warm up 200-1100 nm)<br \/>\n<strong>Zero Drift:<\/strong> &lt; 0.001A\/h after warm up<br \/>\n<strong>Stray Light:<\/strong> &lt;0.05%T at 220 nm and 340 nm<br \/>\n<strong>Noise:<\/strong> \u00b1 0.0001 A @ 500 nm<br \/>\n<strong>Photometric Range:<\/strong> -0.3 \u2013 3 A, 0-200%T<\/p>\n<\/div><\/div> <div class=\"su-column su-column-size-1-2\"><div class=\"su-column-inner su-u-clearfix su-u-trim\">\n<p><strong>Photometric Accuracy:<\/strong> \u00b1 0,5%<br \/>\n<strong>Light source:<\/strong> Tungsten-Halogen &amp; Deuterium<br \/>\n<strong>Detector:<\/strong> Silicon Photodiodes<br \/>\n<strong>Monochromator:<\/strong> 1200 lines\/mm grating<br \/>\n<strong>Connectivity:<\/strong> 2 x USB, Centronic parallel for printers<br \/>\n<strong>User Interface:<\/strong> Keypad &amp; LCD or Camspec Software via PC<br \/>\n<strong>Size:<\/strong> 630mm x 410 mm cm x 280 mm (packed 770 mm x 560 mm x 410 mm)<br \/>\n<strong>Weight:<\/strong> 24 kg (packed 28 kg)<\/p>\n<\/div><\/div><\/div>\n<\/div><div class=\"nav fusion-mobile-tab-nav\"><ul class=\"nav-tabs nav-justified\" role=\"tablist\"><li role=\"presentation\"><a class=\"tab-link\" data-toggle=\"tab\" role=\"tab\" aria-controls=\"tab-ec6298d5e9aa3f32803\" aria-selected=\"false\" tabindex=\"-1\" id=\"mobile-fusion-tab-accessories&amp;options\" href=\"#tab-ec6298d5e9aa3f32803\"><h4 class=\"fusion-tab-heading\">Accessories &amp; Options<\/h4><\/a><\/li><\/ul><\/div><div class=\"tab-pane fade fusion-clearfix\" role=\"tabpanel\" tabindex=\"0\" aria-labelledby=\"fusion-tab-accessories&amp;options\" id=\"tab-ec6298d5e9aa3f32803\">\n<p><strong>The M550 includes the following articles:<\/strong><\/p>\n<ul>\n<li>M550 (variable Bandpass) UV\/VIS-Spectrophotometer<\/li>\n<li>2 precision cell holders<\/li>\n<li>4 x glass cells<\/li>\n<li>2 x silica cells<\/li>\n<li>dust cover &amp; user manual<\/li>\n<\/ul>\n<p><strong>Options (Hardware):<\/strong><\/p>\n<ul>\n<li>M550 (fixed 1.8 nm Bandpass) UVVIS-Spectrophotometer<\/li>\n<li>M550 (fixed 1.0 nm Bandpass) UVVIS-Spectrophotometer<\/li>\n<li>M550-GMP (fixed 1.8 nm Bandpass)<\/li>\n<li>M550-GMP (variable Bandpass) UVVIS-Spectrophotometer<\/li>\n<li>M550 Chroma &#8211; Camspec Integrated colour determination according to ISO11664\/CIE15M501 (1.8 nm Bandpass)<\/li>\n<li>M550 CHROMA &#8211; Spectrophotometer compatible with ILIS software<\/li>\n<\/ul>\n<p><strong>Options (Software):<\/strong><\/p>\n<ul>\n<li>Chroma Spectrum Edition<\/li>\n<li>Chroma Colour Edition<\/li>\n<li>Chroma Glass Edition<\/li>\n<li>Parallel Kinetics Software Package<\/li>\n<li>Repeat Scans Software Package<\/li>\n<\/ul>\n<p><strong>Accessories:<\/strong><\/p>\n<ul>\n<li>Test tube v-type holder (for 100 mm long tubes with 8-25 mm diameter)<\/li>\n<li>Pre-Aligned Deuterium Lamp<\/li>\n<li>Adjustable micro-cell holder<\/li>\n<li>Automatic 6-Position Cell Changer<\/li>\n<li>Thermostatted Auto 6-Cell Changer (requires water bath)<\/li>\n<li>Integrating sphere, 50 mm diameter, for Diffuse %T or %R<\/li>\n<li>Integrating sphere, 50 mm diameter, for Transmittance only<\/li>\n<li>Black and White references for use with integrating sphere<\/li>\n<li>4 cell holder for 5-50 mm cells<\/li>\n<li>4 cell holder for 100 mm cells<\/li>\n<li>Holder for 1 x 100 mm cylindrical cell<\/li>\n<li>Thermostatted 10 mm cell holder (requires water bath)<\/li>\n<li>Processor controlled sipper (requires flow cell)<\/li>\n<li>Peltier system for 10 mm cells (15-40 \u00b0C)<\/li>\n<li>Cell stirrer for 10 mm cells<\/li>\n<li>Printer (Parallel for A4 HP and Epson printers)<\/li>\n<li>Specular Reflectance Accessory (5\u00b0 incident angle)<\/li>\n<li>PC Application Software Package &#8211; control &amp; measurement software (plain software or preinstalled on a PC)<\/li>\n<\/ul>\n<\/div><div class=\"nav fusion-mobile-tab-nav\"><ul class=\"nav-tabs nav-justified\" role=\"tablist\"><li role=\"presentation\"><a class=\"tab-link\" data-toggle=\"tab\" role=\"tab\" aria-controls=\"tab-c458542268928c01019\" aria-selected=\"false\" tabindex=\"-1\" id=\"mobile-fusion-tab-literature\" href=\"#tab-c458542268928c01019\"><h4 class=\"fusion-tab-heading\">Literature<\/h4><\/a><\/li><\/ul><\/div><div class=\"tab-pane fade fusion-clearfix\" role=\"tabpanel\" tabindex=\"0\" aria-labelledby=\"fusion-tab-literature\" id=\"tab-c458542268928c01019\">\n<div class=\"su-row\"><div class=\"su-column su-column-size-1-4\"><div class=\"su-column-inner su-u-clearfix su-u-trim\">\n<strong>Brochure M550 variable bandpass<\/strong><\/p>\n<div class='w3eden'><!-- WPDM Link Template: Default Template -->\n\n<div class=\"link-template-default card mb-2\">\n    <div class=\"card-body\">\n        <div class=\"media\">\n            <div class=\"mr-3 img-48\"><img class=\"wpdm_icon\" alt=\"Icon\" src=\"https:\/\/abacus-lab.de\/wp-content\/plugins\/download-manager\/assets\/file-type-icons\/pdf.svg\" \/><\/div>\n            <div class=\"media-body\">\n                <h3 class=\"package-title\"><a href='https:\/\/abacus-lab.de\/en\/download\/camspec-m550-variable-bandpass-brochure-en\/'>Camspec M550 variable Bandpass Brochure EN<\/a><\/h3>\n                <div class=\"text-muted text-small\"><i class=\"fas fa-copy\"><\/i> 1 file(s) <i class=\"fas fa-hdd ml-3\"><\/i> 1.53 MB<\/div>\n            <\/div>\n            <div class=\"ml-3\">\n                <a href='#unlock' class='wpdm-download-link wpdm-download-locked btn btn-info ' data-package='33565'>Download<\/a>\n            <\/div>\n        <\/div>\n    <\/div>\n<\/div>\n\n<\/div>\n<p><strong>Brochure M550 1.0 nm fixed bandpass<\/strong><\/p>\n<div class='w3eden'><!-- WPDM Link Template: Default Template -->\n\n<div class=\"link-template-default card mb-2\">\n    <div class=\"card-body\">\n        <div class=\"media\">\n            <div class=\"mr-3 img-48\"><img class=\"wpdm_icon\" alt=\"Icon\" src=\"https:\/\/abacus-lab.de\/wp-content\/plugins\/download-manager\/assets\/file-type-icons\/pdf.svg\" \/><\/div>\n            <div class=\"media-body\">\n                <h3 class=\"package-title\"><a href='https:\/\/abacus-lab.de\/en\/download\/camspec-m550-1nm-bandpass-brochure-en\/'>Camspec M550 1nm Bandpass Brochure EN<\/a><\/h3>\n                <div class=\"text-muted text-small\"><i class=\"fas fa-copy\"><\/i> 1 file(s) <i class=\"fas fa-hdd ml-3\"><\/i> 1.53 MB<\/div>\n            <\/div>\n            <div class=\"ml-3\">\n                <a href='#unlock' class='wpdm-download-link wpdm-download-locked btn btn-info ' data-package='33557'>Download<\/a>\n            <\/div>\n        <\/div>\n    <\/div>\n<\/div>\n\n<\/div>\n<\/div><\/div> <div class=\"su-column su-column-size-1-4\"><div class=\"su-column-inner su-u-clearfix su-u-trim\">\n<p><strong>Brochure Chroma Software Package &amp; M550<\/strong><\/p>\n<div class='w3eden'><!-- WPDM Link Template: Default Template -->\n\n<div class=\"link-template-default card mb-2\">\n    <div class=\"card-body\">\n        <div class=\"media\">\n            <div class=\"mr-3 img-48\"><img class=\"wpdm_icon\" alt=\"Icon\" src=\"https:\/\/abacus-lab.de\/wp-content\/plugins\/download-manager\/assets\/file-type-icons\/pdf.svg\" \/><\/div>\n            <div class=\"media-body\">\n                <h3 class=\"package-title\"><a href='https:\/\/abacus-lab.de\/en\/download\/camspec-m500-chroma-brochure-en\/'>Camspec M500 Chroma Brochure EN<\/a><\/h3>\n                <div class=\"text-muted text-small\"><i class=\"fas fa-copy\"><\/i> 1 file(s) <i class=\"fas fa-hdd ml-3\"><\/i> 1.53 MB<\/div>\n            <\/div>\n            <div class=\"ml-3\">\n                <a href='#unlock' class='wpdm-download-link wpdm-download-locked btn btn-info ' data-package='33473'>Download<\/a>\n            <\/div>\n        <\/div>\n    <\/div>\n<\/div>\n\n<\/div>\n<\/div><\/div> <div class=\"su-column su-column-size-1-4\"><div class=\"su-column-inner su-u-clearfix su-u-trim\">\n<p><strong>Brochure M550 1.8 nm fixed bandpass<\/strong><\/p>\n<div class='w3eden'><!-- WPDM Link Template: Default Template -->\n\n<div class=\"link-template-default card mb-2\">\n    <div class=\"card-body\">\n        <div class=\"media\">\n            <div class=\"mr-3 img-48\"><img class=\"wpdm_icon\" alt=\"Icon\" src=\"https:\/\/abacus-lab.de\/wp-content\/plugins\/download-manager\/assets\/file-type-icons\/pdf.svg\" \/><\/div>\n            <div class=\"media-body\">\n                <h3 class=\"package-title\"><a href='https:\/\/abacus-lab.de\/en\/download\/camspec-m550-1p8nm-bandpass-brochure-en\/'>Camspec M550 1.8nm Bandpass Brochure EN<\/a><\/h3>\n                <div class=\"text-muted text-small\"><i class=\"fas fa-copy\"><\/i> 1 file(s) <i class=\"fas fa-hdd ml-3\"><\/i> 1.53 MB<\/div>\n            <\/div>\n            <div class=\"ml-3\">\n                <a href='#unlock' class='wpdm-download-link wpdm-download-locked btn btn-info ' data-package='33568'>Download<\/a>\n            <\/div>\n        <\/div>\n    <\/div>\n<\/div>\n\n<\/div>\n<\/div><\/div> <div class=\"su-column su-column-size-1-4\"><div class=\"su-column-inner su-u-clearfix su-u-trim\">\n<p><strong>SPF\u00a0Brochure M550\u00a0<\/strong><\/p>\n<div class='w3eden'><!-- WPDM Link Template: Default Template -->\n\n<div class=\"link-template-default card mb-2\">\n    <div class=\"card-body\">\n        <div class=\"media\">\n            <div class=\"mr-3 img-48\"><img class=\"wpdm_icon\" alt=\"Icon\" src=\"https:\/\/abacus-lab.de\/wp-content\/plugins\/download-manager\/assets\/file-type-icons\/pdf.svg\" \/><\/div>\n            <div class=\"media-body\">\n                <h3 class=\"package-title\"><a href='https:\/\/abacus-lab.de\/en\/download\/camspec-m550-spf-brochure-en\/'>Camspec M550 SPF Brochure EN<\/a><\/h3>\n                <div class=\"text-muted text-small\"><i class=\"fas fa-copy\"><\/i> 1 file(s) <i class=\"fas fa-hdd ml-3\"><\/i> 1.53 MB<\/div>\n            <\/div>\n            <div class=\"ml-3\">\n                <a href='#unlock' class='wpdm-download-link wpdm-download-locked btn btn-info ' data-package='33561'>Download<\/a>\n            <\/div>\n        <\/div>\n    <\/div>\n<\/div>\n\n<\/div>\n<\/div><\/div><\/div>\n<\/div><div class=\"nav fusion-mobile-tab-nav\"><ul class=\"nav-tabs nav-justified\" role=\"tablist\"><li role=\"presentation\"><a class=\"tab-link\" data-toggle=\"tab\" role=\"tab\" aria-controls=\"tab-56fa9d59519ccb93027\" aria-selected=\"false\" tabindex=\"-1\" id=\"mobile-fusion-tab-videos\" href=\"#tab-56fa9d59519ccb93027\"><h4 class=\"fusion-tab-heading\">Videos<\/h4><\/a><\/li><\/ul><\/div><div class=\"tab-pane fade fusion-clearfix\" role=\"tabpanel\" tabindex=\"0\" aria-labelledby=\"fusion-tab-videos\" id=\"tab-56fa9d59519ccb93027\">\n<p>not available<\/p>\n<\/div><\/div><\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><\/div><\/div><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-3 fusion-parallax-none nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-padding-bottom:30px;--awb-background-image:url(&quot;https:\/\/abacus-lab.com\/wp-content\/uploads\/2018\/07\/BG_15.jpg&quot;);--awb-background-size:cover;\" ><div class=\"fusion-builder-row fusion-row\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-4 fusion_builder_column_3_4 3_4 fusion-three-fourth fusion-column-first\" style=\"--awb-bg-size:cover;width:75%;width:calc(75% - ( ( 4% ) * 0.75 ) );margin-right: 4%;\"><div class=\"fusion-column-wrapper fusion-flex-column-wrapper-legacy\"><div class=\"fusion-text fusion-text-2\"><p>If you are interested in further information you can contact our service department using the <a href=\"https:\/\/abacus-lab.de\/contact\/\">contact form<\/a>.<\/p>\n<\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-5 fusion_builder_column_1_4 1_4 fusion-one-fourth fusion-column-last\" style=\"--awb-bg-size:cover;width:25%;width:calc(25% - ( ( 4% ) * 0.25 ) );\"><div class=\"fusion-column-wrapper fusion-flex-column-wrapper-legacy\"><div class=\"fusion-aligncenter\"><a class=\"fusion-button button-flat button-xlarge button-custom fusion-button-default button-1 fusion-button-default-span \" style=\"--button_accent_color:#ffffff;--button_accent_hover_color:#ffffff;--button_border_hover_color:#ffffff;--button_gradient_top_color:#eba931;--button_gradient_bottom_color:#eba931;--button_gradient_top_color_hover:#eacb91;--button_gradient_bottom_color_hover:#eacb91;\" target=\"_self\" href=\"https:\/\/abacus-lab.de\/contact\/\"><span class=\"fusion-button-text\">request a quote<\/span><\/a><\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><\/div><\/div>\n\n","protected":false},"excerpt":{"rendered":"<p>The spectrometer for high-end analysis in industry and universities<\/p>\n<ul>\n<li>parallel sample &#038; reference beam<\/li>\n<li>Wavelength range 190 &#8211; 1100nm<\/li>\n<li>variable Bandpass &#038; fixed options<\/li>\n<li>Low stray light (&lt; 0.05%T)<\/li>\n<li>GLP compliance possible<\/li>\n<li>Chroma Software availiable (optional)<\/li>\n<\/ul>\n","protected":false},"author":1,"featured_media":35019,"menu_order":0,"comment_status":"open","ping_status":"closed","template":"","format":"standard","meta":{"_mi_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0},"portfolio_category":[184],"portfolio_skills":[],"portfolio_tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v20.2.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>M550 Spectrophotometer - Abacus Analytical Systems<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/abacus-lab.de\/en\/portfolio-items\/m550\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"M550 Spectrophotometer - Abacus Analytical Systems\" \/>\n<meta property=\"og:description\" content=\"The spectrometer for high-end analysis in industry and universities    parallel sample &amp; reference beam  Wavelength range 190 - 1100nm  variable Bandpass &amp; fixed options  Low stray light (&lt; 0.05%T)  GLP compliance possible  Chroma Software availiable (optional)\" \/>\n<meta property=\"og:url\" content=\"https:\/\/abacus-lab.de\/en\/portfolio-items\/m550\/\" \/>\n<meta property=\"og:site_name\" content=\"Abacus Analytical Systems\" \/>\n<meta property=\"article:modified_time\" content=\"2020-12-07T09:08:22+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/abacus-lab.de\/wp-content\/uploads\/2020\/10\/Camspec-M550-Spectrophotometer.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1294\" \/>\n\t<meta property=\"og:image:height\" content=\"1151\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"7 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/abacus-lab.de\/en\/portfolio-items\/m550\/\",\"url\":\"https:\/\/abacus-lab.de\/en\/portfolio-items\/m550\/\",\"name\":\"M550 Spectrophotometer - Abacus Analytical Systems\",\"isPartOf\":{\"@id\":\"https:\/\/abacus-lab.de\/de\/#website\"},\"datePublished\":\"2020-10-05T14:15:59+00:00\",\"dateModified\":\"2020-12-07T09:08:22+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/abacus-lab.de\/en\/portfolio-items\/m550\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/abacus-lab.de\/en\/portfolio-items\/m550\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/abacus-lab.de\/en\/portfolio-items\/m550\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\/\/abacus-lab.de\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Portfolio\",\"item\":\"https:\/\/abacus-lab.de\/de\/portfolio-items\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"M550 Spectrophotometer\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/abacus-lab.de\/de\/#website\",\"url\":\"https:\/\/abacus-lab.de\/de\/\",\"name\":\"Abacus Analytical Systems\",\"description\":\"Analytical Chemistry | Biotechnology | Bioscience\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/abacus-lab.de\/de\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"M550 Spectrophotometer - Abacus Analytical Systems","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/abacus-lab.de\/en\/portfolio-items\/m550\/","og_locale":"en_US","og_type":"article","og_title":"M550 Spectrophotometer - Abacus Analytical Systems","og_description":"The spectrometer for high-end analysis in industry and universities    parallel sample & reference beam  Wavelength range 190 - 1100nm  variable Bandpass & fixed options  Low stray light (&lt; 0.05%T)  GLP compliance possible  Chroma Software availiable (optional)","og_url":"https:\/\/abacus-lab.de\/en\/portfolio-items\/m550\/","og_site_name":"Abacus Analytical Systems","article_modified_time":"2020-12-07T09:08:22+00:00","og_image":[{"width":1294,"height":1151,"url":"https:\/\/abacus-lab.de\/wp-content\/uploads\/2020\/10\/Camspec-M550-Spectrophotometer.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"7 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/abacus-lab.de\/en\/portfolio-items\/m550\/","url":"https:\/\/abacus-lab.de\/en\/portfolio-items\/m550\/","name":"M550 Spectrophotometer - Abacus Analytical Systems","isPartOf":{"@id":"https:\/\/abacus-lab.de\/de\/#website"},"datePublished":"2020-10-05T14:15:59+00:00","dateModified":"2020-12-07T09:08:22+00:00","breadcrumb":{"@id":"https:\/\/abacus-lab.de\/en\/portfolio-items\/m550\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/abacus-lab.de\/en\/portfolio-items\/m550\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/abacus-lab.de\/en\/portfolio-items\/m550\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/abacus-lab.de\/en\/"},{"@type":"ListItem","position":2,"name":"Portfolio","item":"https:\/\/abacus-lab.de\/de\/portfolio-items\/"},{"@type":"ListItem","position":3,"name":"M550 Spectrophotometer"}]},{"@type":"WebSite","@id":"https:\/\/abacus-lab.de\/de\/#website","url":"https:\/\/abacus-lab.de\/de\/","name":"Abacus Analytical Systems","description":"Analytical Chemistry | Biotechnology | Bioscience","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/abacus-lab.de\/de\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/abacus-lab.de\/en\/wp-json\/wp\/v2\/avada_portfolio\/34729"}],"collection":[{"href":"https:\/\/abacus-lab.de\/en\/wp-json\/wp\/v2\/avada_portfolio"}],"about":[{"href":"https:\/\/abacus-lab.de\/en\/wp-json\/wp\/v2\/types\/avada_portfolio"}],"author":[{"embeddable":true,"href":"https:\/\/abacus-lab.de\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/abacus-lab.de\/en\/wp-json\/wp\/v2\/comments?post=34729"}],"version-history":[{"count":9,"href":"https:\/\/abacus-lab.de\/en\/wp-json\/wp\/v2\/avada_portfolio\/34729\/revisions"}],"predecessor-version":[{"id":34734,"href":"https:\/\/abacus-lab.de\/en\/wp-json\/wp\/v2\/avada_portfolio\/34729\/revisions\/34734"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/abacus-lab.de\/en\/wp-json\/wp\/v2\/media\/35019"}],"wp:attachment":[{"href":"https:\/\/abacus-lab.de\/en\/wp-json\/wp\/v2\/media?parent=34729"}],"wp:term":[{"taxonomy":"portfolio_category","embeddable":true,"href":"https:\/\/abacus-lab.de\/en\/wp-json\/wp\/v2\/portfolio_category?post=34729"},{"taxonomy":"portfolio_skills","embeddable":true,"href":"https:\/\/abacus-lab.de\/en\/wp-json\/wp\/v2\/portfolio_skills?post=34729"},{"taxonomy":"portfolio_tags","embeddable":true,"href":"https:\/\/abacus-lab.de\/en\/wp-json\/wp\/v2\/portfolio_tags?post=34729"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}